Palm Abbe Digital Refractometer for Dairy – Raw Milk Quality: Blood Serum and Total Protein – Solids in Milk – Hydration
Original price was: 6.851 SEK.6.767 SEKCurrent price is: 6.767 SEK.
The DD-3 digital dairy refractometer provides reliable estimates of raw milk quality, blood serum total protein concentration, percentage of solids in waste milk, and calf hydration. MISCO’s Digital-Dairy™ dairy refractometers are specifically designed to help professional dairy farmers and calf raisers achieve healthy calves. They are rugged enough to withstand the demands of a farm, yet still deliver laboratory-grade readings.
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 kr excl. VAT
- Refractometers from Misco, Atago and Extech
- Call us +46 8 753 00 04
Description
52-PA203X-003-098-105-466
52-PA203X-003-098-105-466
| Scale | Medium | Unit of Measurement | Display Shows | Measuring Range | Resolution | Precision |
|---|---|---|---|---|---|---|
| 003 | Brix | Brix | Brix | 0 to 85 | 0.1 | 0.1 |
| 098 | Urine – Large Animal | Specific Gravity (D20/20) | LA URIN SG | 1.0000 to 1.0650 | 0.0001 | 0.0005 |
| 105 | Blood – Animal – Total Protein with Refractometer (TPr) | G/dL | Protein g/dl | 1 to 14 | 0.1 | 0.1 |
| 466 | Waste Milk Solids | % Total Solids | Milk Solids% | 5 to 15 | 0.1 | 0.5 |
The DD-3 digital dairy refractometer provides reliable estimates of raw milk quality (Brix method), blood serum concentration, percentage of solids in waste milk, and calf hydration. MISCO’s Digital-Dairy™ dairy refractometers are specifically designed to help professional dairy farmers and calf raisers achieve healthy calves. They are rugged enough to withstand the demands of a farm, yet still provide laboratory-grade readings.
Calves are displaced, and dairy farmers will immediately recognize the importance of raw milk quality. The Digital-Dairy DD-3 refractometer can test for raw milk quality using the Brix method. A measure of blood serum concentration level can be used as an indication of IgG passive transfer. Blood samples must be spun in a centrifuge, or left undisturbed for 24 hours, to separate the plasma from whole blood before testing on the refractometer.
Unsaleable waste milk has been used as feed for calves for many years and constitutes a readily available source of nutrition, has several other uses, and is cheaper to feed than milk. However, dry matter and bacterial levels present two problems associated with waste milk feeding. Since the DD-3 digital dairy refractometer reads directly in dry matter, it takes only a few drops of milk to quickly determine the dry matter percentage and adjust it to the desired level with calf milk replacer. Another quick test for bacterial contamination and milk spoilage can be performed using a pH meter, also from MISCO.
Mild dehydration can occur without symptoms until it is almost too late. If, due to scours or other causes, calves can lose up to 6 percent of their body weight in fluid before there is any visual indication of dehydration. If dehydration is caught early enough, fluid therapy can reverse it, but the most important thing is to catch it early. The large animal urine density scale on the DD-3 digital dairy refractometer can be used to quickly identify at-risk calves.
For any test, only a few drops of sample are needed to fill the stainless steel sample dish. The sapphire glass measuring surface, the second hardest material after diamond, withstands many years of wear. A simple and user-friendly interface consists of two buttons: one for readings and the other to step through various menu options. A large 24-character backlit LCD display is easy to read, even in low light, while an evaporation cover prevents evaporation and keeps out stray light.
Protection against erroneous readings due to temperature differences, a major concern with refractometer measurements, is ensured with non-linear temperature compensation. Automatic temperature compensation for liquid samples between 10 and 40 °C (50 to 104 °F). Digital-Dairy refractometers can be easily calibrated with water.
Be sure to obtain your free copy of “MISCO Digital-Dairy refractometers – handling waste milk dry matter, raw milk quality and dehydration in Dairy Calves.”
MISCO refractometers are manufactured in the USA. MISCO is a proud member of the Dairy Calf or Heifer Association & a supporter of the Ohio Farm Bureau.
Specification
52-PA203X-003-098-105-466
52-PA203X-003-098-105-466
| Scale | Medium | Unit of Measurement | Display Shows | Measuring Range | Resolution | Precision |
|---|---|---|---|---|---|---|
| 003 | Brix | Brix | Brix | 0 to 85 | 0.1 | 0.1 |
| 098 | Urine – Large Animal | Specific Gravity (D20/20) | LA URIN SG | 1.0000 to 1.0650 | 0.0001 | 0.0005 |
| 105 | Blood – Animal – Total Protein with Refractometer (TPr) | G/dL | Protein g/dl | 1 to 14 | 0.1 | 0.1 |
| 466 | Waste Milk Solids | % Total Solids | Milk Solids% | 5 to 15 | 0.1 | 0.5 |
The DD-3 digital dairy refractometer provides reliable estimates of raw milk quality (Brix method), blood serum concentration, percentage of solids in waste milk, and calf hydration. MISCO’s Digital-Dairy™ dairy refractometers are specifically designed to help professional dairy farmers and calf raisers achieve healthy calves. They are rugged enough to withstand the demands of a farm, yet still provide laboratory-grade readings.
Calves are displaced, and dairy farmers will immediately recognize the importance of raw milk quality. The Digital-Dairy DD-3 refractometer can test for raw milk quality using the Brix method. A measure of blood serum concentration level can be used as an indication of IgG passive transfer. Blood samples must be spun in a centrifuge, or left undisturbed for 24 hours, to separate the plasma from whole blood before testing on the refractometer.
Unsaleable waste milk has been used as feed for calves for many years and constitutes a readily available source of nutrition, has several other uses, and is cheaper to feed than milk. However, dry matter and bacterial levels present two problems associated with waste milk feeding. Since the DD-3 digital dairy refractometer reads directly in dry matter, it takes only a few drops of milk to quickly determine the dry matter percentage and adjust it to the desired level with calf milk replacer. Another quick test for bacterial contamination and milk spoilage can be performed using a pH meter, also from MISCO.
Mild dehydration can occur without symptoms until it is almost too late. If, due to scours or other causes, calves can lose up to 6 percent of their body weight in fluid before there is any visual indication of dehydration. If dehydration is caught early enough, fluid therapy can reverse it, but the most important thing is to catch it early. The large animal urine density scale on the DD-3 digital dairy refractometer can be used to quickly identify at-risk calves.
For any test, only a few drops of sample are needed to fill the stainless steel sample dish. The sapphire glass measuring surface, the second hardest material after diamond, withstands many years of wear. A simple and user-friendly interface consists of two buttons: one for readings and the other to step through various menu options. A large 24-character backlit LCD display is easy to read, even in low light, while an evaporation cover prevents evaporation and keeps out stray light.
Protection against erroneous readings due to temperature differences, a major concern with refractometer measurements, is ensured with non-linear temperature compensation. Automatic temperature compensation for liquid samples between 10 and 40 °C (50 to 104 °F). Digital-Dairy refractometers can be easily calibrated with water.
Be sure to obtain your free copy of “MISCO Digital-Dairy refractometers – handling waste milk dry matter, raw milk quality and dehydration in Dairy Calves.”
MISCO refractometers are manufactured in the USA. MISCO is a proud member of the Dairy Calf or Heifer Association & a supporter of the Ohio Farm Bureau.