Hoppa till innehåll
Free shipping on orders over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Standard Brix Refractometer Shows the Wrong Sugar Content in WortThe Right Sugar Content in the Wort and the Right Antifreeze Protection in the Cooling System Can Be Measured with the Same InstrumentWort and glycol circuits can be checked with the same instrument if the refractometer has the right scalesSeawater Salinity Readings Go Wrong When the Instrument Only Counts Sodium ChlorideWhy the Brix Value Gives the Wrong Sugar Content in Wort, and How the Same Instrument Checks the Glycol in Your Cooling SystemSugar content in the sample changes with temperature, and you only notice when the batch is offSame sample, different sugar reading: how temperature-compensated refractometry ends the debateWhy measure in Brix when the liquid isn’t made of sucrose?A Few Drops Are Enough to See Whether the Concentration of the Liquid Is RightSame sample, same value: why a digital refractometer gives more reliable Brix measurement than reading by eyeVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Standard Brix Refractometer Shows the Wrong Sugar Content in WortThe Right Sugar Content in the Wort and the Right Antifreeze Protection in the Cooling System Can Be Measured with the Same InstrumentWort and glycol circuits can be checked with the same instrument if the refractometer has the right scalesSeawater Salinity Readings Go Wrong When the Instrument Only Counts Sodium ChlorideWhy the Brix Value Gives the Wrong Sugar Content in Wort, and How the Same Instrument Checks the Glycol in Your Cooling SystemSugar content in the sample changes with temperature, and you only notice when the batch is offSame sample, different sugar reading: how temperature-compensated refractometry ends the debateWhy measure in Brix when the liquid isn’t made of sucrose?A Few Drops Are Enough to See Whether the Concentration of the Liquid Is RightSame sample, same value: why a digital refractometer gives more reliable Brix measurement than reading by eye
Item number 52-PA203X-009-800-802

Palm Abbe Digital Refractometer for Brewing: Wort, Dissolved Solids & Specific Gravity (D20/20°C), Propylene Glycol Freezing Point °C

6.851 SEK

In stock

Multi-scale digital beer refractometer for measuring dissolved solids, specific gravity of wort, and propylene glycol antifreeze. This refractometer provides a much more accurate indication of true total sugar content and wort, unlike an estimate from a saccharose-based Brix refractometer. These beer scales are automatically temperature-compensated specifically for wort. The propylene glycol scale is ideal for propylene glycol antifreeze in wort chillers and cooling systems.

Request a quote 52-PA203X-009-800-802

Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%

  • Free shipping on orders over 3000 kr excl. VAT
  • Refractometers from Misco, Atago and Extech
  • Call us +46 8 753 00 04

Category:

Description
Scale Medium Unit of Measurement Display Shows Measuring Range Resolution Accuracy
009 Propylene glycol Freezing point °C PG freeze °C 0 to -51 1 1
800 Beer (deadlines sugars) Dissolved solids (deadlines sugars) Wort %DS 0 to 30 0.1 0.1
802 Beer (deadlines sugars) Specific gravity (D20/20 °C) Deadlines D20/20C 1.000 to 1.127 0.001 0.001

MISCO digital beer refractometer with deadlines dissolved solids, Density D 20/20, and propylene glycol freezing point (°C) scales

This multi-scale refractometer is equipped to measure beer dissolved solids (total sugars), specific gravity (D 20/20 °C), and propylene glycol freezing point in °C. The dissolved solids and specific gravity scales are ideal for accurately measuring the sugar content of the wort used in making beer. These two scales are based on mathematical relationships between actual wort sugars and refractive index, providing a more accurate indication of true sugar content and can be used interchangeably with Brix, °Plato, and top-of-the-line units in calculators and equations. The propylene glycol scale is ideal for measuring propylene glycol heat transfer fluid in wort chillers and cooling systems.

Whether you are a beer chemist working for a multinational brewery or a passionate brewer crafting one-of-a-kind beers in your own home, the goal of the MISCO digital beer refractometer is to help you by providing the most accurate possible beer measurements from start to finish.

Misco’s digital beer refractometer is not just a standard Brix refractometer. The MISCO Pro-Brewing scales™ are scientifically derived from a beer model with a very complex sugar profile, which is strongly influenced by maltose and specific to beer. There is very little sucrose in beer, and measurements and temperature compensation are naturally much more accurate than sucrose-based Brix refractometers(See our free technical bulletins under the Materials tab).Furthermore, because the refractometer is made specifically for beer, the user no longer needs to use a refractometer correction factor when converting dissolved solids or specific gravity readings in beer calculators.

Fast, convenient, and easy to use, the MISCO digital beer refractometer requires only a fraction of the sample size needed by traditional hydrometers. Simply place one or two drops of beer on the stainless steel prism and press a button. The beer refractometer provides an almost immediate digital reading on a large backlit LCD display. The digital display eliminates the subjectivity involved in interpreting where a boundary line crosses small scale divisions.

Precision is guaranteed thanks to MISCO’s environmentally friendly; proven Optical Engine®, which is the core of every digital beer refractometer. The Optical Engine features high-precision sapphire optics, the second hardest material after diamond, which improves the speed and accuracy of temperature measurements. Competing digital refractometers use only glass prisms. A 1,024-element high-resolution detector array contains more than eight times the resolution of competing 128-element low-definition detector groups. Misco’s array has a resolution of more than 3,256 pixels per inch (ppi) compared to 400 dpi resolution in competing digital refractometers. The result is an instrument that is more robust and more accurate.

Non-linear temperature compensation is specific to beer and sucrose, and automatically ensures that liquids read between 10 and 40 °C (50 to 104 °F) are measured accurately. Calibration is automatic and does not require the use of special calibration solutions or tools. The beer refractometer calibrates automatically to water and is ready to use within seconds. No more screws to turn and nothing to adjust. The results can also be localized to display in English, German, Spanish, French, and Russian.

*Digital beer refractometer shown here with optional rubber Armor jacket – available separately.

Specification
Scale Medium Unit of Measurement Display Shows Measuring Range Resolution Accuracy
009 Propylene glycol Freezing point °C PG freeze °C 0 to -51 1 1
800 Beer (deadlines sugars) Dissolved solids (deadlines sugars) Wort %DS 0 to 30 0.1 0.1
802 Beer (deadlines sugars) Specific gravity (D20/20 °C) Deadlines D20/20C 1.000 to 1.127 0.001 0.001

MISCO digital beer refractometer with deadlines dissolved solids, Density D 20/20, and propylene glycol freezing point (°C) scales

This multi-scale refractometer is equipped to measure beer dissolved solids (total sugars), specific gravity (D 20/20 °C), and propylene glycol freezing point in °C. The dissolved solids and specific gravity scales are ideal for accurately measuring the sugar content of the wort used in making beer. These two scales are based on mathematical relationships between actual wort sugars and refractive index, providing a more accurate indication of true sugar content and can be used interchangeably with Brix, °Plato, and top-of-the-line units in calculators and equations. The propylene glycol scale is ideal for measuring propylene glycol heat transfer fluid in wort chillers and cooling systems.

Whether you are a beer chemist working for a multinational brewery or a passionate brewer crafting one-of-a-kind beers in your own home, the goal of the MISCO digital beer refractometer is to help you by providing the most accurate possible beer measurements from start to finish.

Misco’s digital beer refractometer is not just a standard Brix refractometer. The MISCO Pro-Brewing scales™ are scientifically derived from a beer model with a very complex sugar profile, which is strongly influenced by maltose and specific to beer. There is very little sucrose in beer, and measurements and temperature compensation are naturally much more accurate than sucrose-based Brix refractometers(See our free technical bulletins under the Materials tab).Furthermore, because the refractometer is made specifically for beer, the user no longer needs to use a refractometer correction factor when converting dissolved solids or specific gravity readings in beer calculators.

Fast, convenient, and easy to use, the MISCO digital beer refractometer requires only a fraction of the sample size needed by traditional hydrometers. Simply place one or two drops of beer on the stainless steel prism and press a button. The beer refractometer provides an almost immediate digital reading on a large backlit LCD display. The digital display eliminates the subjectivity involved in interpreting where a boundary line crosses small scale divisions.

Precision is guaranteed thanks to MISCO’s environmentally friendly; proven Optical Engine®, which is the core of every digital beer refractometer. The Optical Engine features high-precision sapphire optics, the second hardest material after diamond, which improves the speed and accuracy of temperature measurements. Competing digital refractometers use only glass prisms. A 1,024-element high-resolution detector array contains more than eight times the resolution of competing 128-element low-definition detector groups. Misco’s array has a resolution of more than 3,256 pixels per inch (ppi) compared to 400 dpi resolution in competing digital refractometers. The result is an instrument that is more robust and more accurate.

Non-linear temperature compensation is specific to beer and sucrose, and automatically ensures that liquids read between 10 and 40 °C (50 to 104 °F) are measured accurately. Calibration is automatic and does not require the use of special calibration solutions or tools. The beer refractometer calibrates automatically to water and is ready to use within seconds. No more screws to turn and nothing to adjust. The results can also be localized to display in English, German, Spanish, French, and Russian.

*Digital beer refractometer shown here with optional rubber Armor jacket – available separately.

PDF (4)
Reviews (0)

There are no reviews yet.

Be the first to review

Your e-mail address is not published.

Your rating *