Digital refractometer for measuring urea concentration in diesel
Original price was: 4.547 SEK.4.431 SEKCurrent price is: 4.431 SEK.
Urea Refractometer for testing Urea-based
Diesel Exhaust Fluid (DEF / AdBlue)
Concentration in Selective Catalytic
Reduction (SCR) equipped diesel engines
Palm Abbe DEF-201 will defeat those who try to cheat
Volume discount: 5 pcs: 2% · 10 pcs: 3% · 25 pcs: 5%
- Free shipping on orders over 3000 kr excl. VAT
- Refractometers from Misco, Atago and Extech
- Call us +46 8 753 00 04
Description
52-DEF1
52-DEF1
Urea Refractometer for testing Urea-based
Diesel Exhaust Fluid (DEF / AdBlue)
Concentration in Selective Catalytic
Reduction (SCR) Equipped Diesel Engines
Palm Abbe DEF-201 will defeat those who try to cheat.
Diesel-powered vehicles will be required to meet strict new EPA emission guidelines starting in 2010. In preparation, manufacturers are employing a number of strategies to comply with these regulations. Selective Catalytic Reduction (SCR) is one such technology.
Selective Catalytic Reduction systems use liquid urea, a nitrogen-based compound, to treat diesel exhaust before it enters a special catalyst. The liquid is called Diesel Exhaust Fluid (DEF) in the USA and AdBlue® in Europe. It consists of a very specific concentration of a water solution of urea in deionized water. Sprayed into the hot exhaust as a fine mist, the urea converts to ammonia and transforms harmful nitrogen oxides (NOx) into harmless nitrogen gas and water vapor.
Palm Abbe is the best defense against diluted DEF.
The correct concentration of Diesel Exhaust Fluid (DEF) is critical for reducing harmful nitrogen oxide emissions and extending the life of SCR components. Even concentration variations of as little as +/-0.8% will prevent a DEF liquid from meeting the requirements regulated by International Organization for Standardization (ISO) standards. DEF dilution or contamination can affect system performance and maintenance costs. The biggest contamination threat is water dilution, but without the right tool, it is nearly impossible to know if a DEF supply has been diluted.
Get concrete results in just a few seconds.
The Misco Palm Abbe DEF-201 refractometer is the ideal method for testing DEF liquid to ensure it is at the correct concentration and has not been diluted or tampered with. It takes only a few drops of DEF and a couple of seconds to perform a test, and the result is accurate to +/-0.1% urea concentration.
Once a few drops of the sample have been added to the stainless steel well, it takes only pressing a single button to initiate a reading. Within seconds, the urea concentration will be displayed on the large 24-character backlit LCD display. The refractometer can also be calibrated to water with a single button press.
The key to the precision and accuracy of the Misco refractometer is its proprietary optical engine. A combination of high-index sapphire optics and a 1024-element detector array. Special hardware and software automatically temperature-compensate readings over a wide temperature range.
The Misco Palm Abbe is the definitive choice in DEF Testing.
The American Petroleum Institute (API), a non-profit industry organization and advocacy group for the oil and natural gas industry, is responsible for certifying producers of Diesel Exhaust Fluid (DEF) for Selective Catalytic Reduction (SCR) equipped diesel engines in North America. The best way to ensure a good DEF liquid is to only purchase urea that carries API certification and frequently test the liquid with a Misco refractometer to ensure it meets quality requirements.
Only a Refractometer can tell if it is definitely DEF.
Alternatives include additional scales for measuring urea density, specific gravity, and freezing point. Similarly, engine coolant concentration and freezing point, brake fluid water content or boiling point, and windshield washer fluid. It also features a rubberized jacket (in one of three different colors) and a virtually indestructible carrying case.
Specification
52-DEF1
52-DEF1
Urea Refractometer for testing Urea-based
Diesel Exhaust Fluid (DEF / AdBlue)
Concentration in Selective Catalytic
Reduction (SCR) Equipped Diesel Engines
Palm Abbe DEF-201 will defeat those who try to cheat.
Diesel-powered vehicles will be required to meet strict new EPA emission guidelines starting in 2010. In preparation, manufacturers are employing a number of strategies to comply with these regulations. Selective Catalytic Reduction (SCR) is one such technology.
Selective Catalytic Reduction systems use liquid urea, a nitrogen-based compound, to treat diesel exhaust before it enters a special catalyst. The liquid is called Diesel Exhaust Fluid (DEF) in the USA and AdBlue® in Europe. It consists of a very specific concentration of a water solution of urea in deionized water. Sprayed into the hot exhaust as a fine mist, the urea converts to ammonia and transforms harmful nitrogen oxides (NOx) into harmless nitrogen gas and water vapor.
Palm Abbe is the best defense against diluted DEF.
The correct concentration of Diesel Exhaust Fluid (DEF) is critical for reducing harmful nitrogen oxide emissions and extending the life of SCR components. Even concentration variations of as little as +/-0.8% will prevent a DEF liquid from meeting the requirements regulated by International Organization for Standardization (ISO) standards. DEF dilution or contamination can affect system performance and maintenance costs. The biggest contamination threat is water dilution, but without the right tool, it is nearly impossible to know if a DEF supply has been diluted.
Get concrete results in just a few seconds.
The Misco Palm Abbe DEF-201 refractometer is the ideal method for testing DEF liquid to ensure it is at the correct concentration and has not been diluted or tampered with. It takes only a few drops of DEF and a couple of seconds to perform a test, and the result is accurate to +/-0.1% urea concentration.
Once a few drops of the sample have been added to the stainless steel well, it takes only pressing a single button to initiate a reading. Within seconds, the urea concentration will be displayed on the large 24-character backlit LCD display. The refractometer can also be calibrated to water with a single button press.
The key to the precision and accuracy of the Misco refractometer is its proprietary optical engine. A combination of high-index sapphire optics and a 1024-element detector array. Special hardware and software automatically temperature-compensate readings over a wide temperature range.
The Misco Palm Abbe is the definitive choice in DEF Testing.
The American Petroleum Institute (API), a non-profit industry organization and advocacy group for the oil and natural gas industry, is responsible for certifying producers of Diesel Exhaust Fluid (DEF) for Selective Catalytic Reduction (SCR) equipped diesel engines in North America. The best way to ensure a good DEF liquid is to only purchase urea that carries API certification and frequently test the liquid with a Misco refractometer to ensure it meets quality requirements.
Only a Refractometer can tell if it is definitely DEF.
Alternatives include additional scales for measuring urea density, specific gravity, and freezing point. Similarly, engine coolant concentration and freezing point, brake fluid water content or boiling point, and windshield washer fluid. It also features a rubberized jacket (in one of three different colors) and a virtually indestructible carrying case.

There are no reviews yet.