Hoppa till innehåll
Free shipping on orders over 3000 kr excl. VAT! Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%
Volume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Standard Brix Refractometer Shows the Wrong Sugar Content in WortThe Right Sugar Content in the Wort and the Right Antifreeze Protection in the Cooling System Can Be Measured with the Same InstrumentWort and glycol circuits can be checked with the same instrument if the refractometer has the right scalesSeawater Salinity Readings Go Wrong When the Instrument Only Counts Sodium ChlorideWhy the Brix Value Gives the Wrong Sugar Content in Wort, and How the Same Instrument Checks the Glycol in Your Cooling SystemSugar content in the sample changes with temperature, and you only notice when the batch is offSame sample, different sugar reading: how temperature-compensated refractometry ends the debateWhy measure in Brix when the liquid isn’t made of sucrose?A Few Drops Are Enough to See Whether the Concentration of the Liquid Is RightSame sample, same value: why a digital refractometer gives more reliable Brix measurement than reading by eyeVolume discount: 5 pcs 2% · 10 pcs 3% · 25 pcs 5%Why a Standard Brix Refractometer Shows the Wrong Sugar Content in WortThe Right Sugar Content in the Wort and the Right Antifreeze Protection in the Cooling System Can Be Measured with the Same InstrumentWort and glycol circuits can be checked with the same instrument if the refractometer has the right scalesSeawater Salinity Readings Go Wrong When the Instrument Only Counts Sodium ChlorideWhy the Brix Value Gives the Wrong Sugar Content in Wort, and How the Same Instrument Checks the Glycol in Your Cooling SystemSugar content in the sample changes with temperature, and you only notice when the batch is offSame sample, different sugar reading: how temperature-compensated refractometry ends the debateWhy measure in Brix when the liquid isn’t made of sucrose?A Few Drops Are Enough to See Whether the Concentration of the Liquid Is RightSame sample, same value: why a digital refractometer gives more reliable Brix measurement than reading by eye

Palm Abbe for Splenda and Sucralose: 600 Times Sweeter Than Sugar, Discovered by Accident in 1976, Now in a Refractometer with Two Scales

Published July 8, 2026 at 22:07

1976 in a lab at Queen Elizabeth College in London: professor Leslie Hough and his doctoral student Shashikant Phadnis were working on halogenated sucrose derivatives for industrial use. Hough told Phadnis to TEST one of the compounds — which in a chemical lab context means titration, chromatography or similar. Phadnis misheard and thought he was being told to TASTE it. He dipped his finger in compound 4-1′,6′-trichlorosucrose and put it in his mouth. The compound was 600 times sweeter than ordinary table sugar. That’s how sucralose came about. Fifteen years later it was approved for consumption in Canada (1991), the US (1998) and the EU (2004). Today it’s the most common high-intensity sweetener in sugar-free soft drinks, caffeine tablets and confectionery products.

The difference between sucralose and Splenda

Chemically, sucralose is the individual molecule — the same every time, regardless of manufacturer. Splenda, on the other hand, is a commercial brand from McNeil Nutritionals (now Heartland Food Products Group) consisting of sucralose plus bulking agents: dextrose and maltodextrin. The reason: sucralose is SO potent that a single serving (equivalent to a teaspoon of sugar) weighs only 1-2 mg. That’s impractical for consumers to handle. The bulking agents give Splenda a volume that matches table sugar teaspoon-for-teaspoon.

Consequence for refractometric measurement: the refractive index (n) of pure sucralose in water differs from the n of a Splenda mixture in the same water. The Palm Abbe model 52-SPLENDA therefore has TWO separate calibration curves:

  • Scale 1: Pure sucralose — direct chemical analysis, used by sucralose manufacturers (e.g. Tate & Lyle production plants).
  • Scale 2: Splenda blend — for food QC when using the commercial powder.

Basic specifications

  • Manufacturer: Misco (USA)
  • Model: Palm Abbe 4th generation, 52-SPLENDA
  • Scales: 2 (sucralose and Splenda)
  • Accuracy: ±1% of reading
  • Automatic temperature compensation: 0-50 °C
  • Sample volume: 2-3 drops
  • Measurement time: ~3 seconds
  • Calibration: One-button with pure water
  • Sensor cell: Stainless steel with sapphire window
  • Housing: Heavy-duty plastic, hinged protective cover

Palm Abbe refractometer for Splenda and sucralose with dual scale

Sucralose in modern food production

Global consumption has grown from ~4,000 tons per year at the time of EU approval in 2004 to >30,000 tons per year today. Where sucralose is used in practice:

  • Sugar-free soft drinks: Pepsi Max, Coca-Cola Zero, Fanta Zero. Typically 25-45 mg sucralose per 33 cl can.
  • Sports drinks and protein shakes: BCAA powders, flavored whey protein.
  • Sugar-free yogurt products: Actimel, Skyr, Activia.
  • Baking industry: Sugar-free cakes, ice cream, preserves. Sucralose is heat-stable up to ~120 °C.
  • Pharmaceuticals and dietary supplements: Flavoring bitter medicine. Vitamin tablets, cough medicines.
  • Dental care products: Sugar-free toothpaste, mouth spray.
  • Diabetic-friendly products: Target market for the whole ”sugar-free” range.

Food production control: refractometric verification at incoming inspection of purchased Splenda (2-4 times per month at larger producers), as well as final production control to confirm that the final concentration matches the recipe.

Regulatory limits

The European Commission has set the ADI (Acceptable Daily Intake) for sucralose at 15 mg per kg body weight per day. For a 70 kg adult: 1,050 mg per day. At 25 mg per 33 cl can, 42 cans per day would be required to reach the ADI — practically impossible.

The food industry has regulatory upper limits for sucralose concentration in various product categories (EU regulation 1129/2011). Refractometric control during production ensures these limits are never exceeded.

Calibration routines

Single-point calibration with pure water is a daily routine (30 seconds). Annual verification against a reference solution (5% sucralose in water) is recommended for production QC documentation. The refractometer can be used across the 0-50 °C range — during warm processes (ice cream production at 40 °C) it works without added cooling.

What you get for the money

Palm Abbe 52-SPLENDA with dual scale for sucralose and Splenda, ±1% accuracy, automatic temperature compensation 0-50 °C, stainless steel sensor cell with sapphire window, one-button calibration, heavy-duty plastic housing with hinged protective cover, sample volume 2-3 drops, measurement time ~3 seconds. 5,394 SEK.

For food manufacturers using sucralose or Splenda in their product range, this instrument is standard equipment in the production lab. Incoming control of purchased goods, final product QC, batch documentation for HACCP and ISO 22000.

Read more: Palm Abbe for Splenda and sucralose in the shop →

More news

All news