Published July 3, 2026 at 07:15
The saltwater aquarium is one of the most sensitive household systems there is. Reef coral and saltwater fish may look like hardy creatures with their spines, thick shells and colorful patterns — but they are evolutionarily adapted to very narrow salinity tolerances. Seawater around the globe sits stably around 35 ppt (parts per thousand, grams of salt per kilogram of water). A reef aquarium or marine saltwater tank must maintain the same level to simulate natural living conditions. Deviations of more than ±3 ppt stress the system; deviations of ±5 ppt or more can be fatal within a week. Being able to measure this accurately isn’t a luxury — it’s basic operation.
What ppt means — and why not ”%”
Salinity has historically been measured in different units depending on tradition:
- ppt (parts per thousand): Grams of salt per kilogram of water. 35 ppt = 35 grams of salt per liter. Standard in marine biology.
- PSU (Practical Salinity Units): Practically identical to ppt for natural seawater. Standard in oceanography.
- SG (Specific Gravity): The density of the liquid relative to pure water. Seawater has an SG around 1.025. Common in the aquarium trade.
- % salt: Avoided in serious aquarium keeping because it’s ambiguous (weight-based or volume-based?).
The RF20 salinity refractometer measures on the ppt scale from 0 (pure water) to 100 ppt (extremely salty water — the Dead Sea at 340 ppt is outside the range, but that’s rarely relevant for aquarium keeping). The scale is linear and easy to read; the 35 ppt line is clearly visible.
Why a refractometer, not a hydrometer
The classic method of measuring salinity is a hydrometer — an instrument that measures density by floating in the liquid. Hydrometers are cheap (100-300 SEK) but have several practical drawbacks:
Requires a large sample: The hydrometer needs a test cylinder with at least 50-100 ml of water. For the aquarium, that means scooping out water with a glass cup, measuring, and pouring it back — a procedure with risks (contamination, spills).
Slow reading: The liquid needs time to stabilize and the hydrometer must stop moving before it can be read. Total time: 2-3 minutes.
Temperature dependent: The hydrometer is typically calibrated for a specific temperature (usually 25 °C). In warmer or colder water, the operator has to compensate manually using tables — a source of error.
Fragile: Glass construction. A hydrometer dropped onto the rock base of the aquarium is destroyed.
The RF20 refractometer solves all these problems: 2-3 drops are enough, the measurement takes 30 seconds, automatic temperature compensation (ATC) from 10-30 °C is built in, and the compact plastic construction withstands handling.
How the measurement is done
- Take 2-3 drops of aquarium water with the included pipette.
- Place the drops on the refractometer’s prism.
- Close the cover and hold the instrument up toward daylight or a strong lamp.
- Look through the eyepiece and read the boundary between light and dark on the scale.
- The ppt value at the boundary is the salinity.
Total time: 30 seconds. Simple enough to do once a day as part of the morning routine.
Calibration
The refractometer is calibrated with pure water (which should read 0 ppt) and the included calibration fluid. Adjustment is made with a small screwdriver included in the package. A calibrated refractometer stays accurate for months; calibrating once a month is fully sufficient for hobby use.
Where the salinity refractometer proves its worth
Saltwater aquariums and reef tanks: Daily monitoring of salinity. Evaporation raises salinity — topping up with fresh water counteracts it. Under-measuring evaporation quickly creates problems.
Professional aquaculture: Marine fish farming, shrimp farming, oyster and mussel cultivation. Salinity is one of the key parameters determining growth and survival.
Zoos and public aquariums: Where large systems with hundreds of species must be kept in a simulated natural environment. Regular measurement is part of systematic maintenance.
Seawater research: Field measurement of salinity in oceanographic studies, coastal monitoring, estuary areas. A portable refractometer is a standard part of a researcher’s kit.
Swimming pool and spa operation: Some swimming pools and spa facilities use saltwater (natural or electrolysis-generated from ordinary salt). Checking the salt level is important for hygienic treatment.
Catering and restaurants: Salting of liquids for various culinary processes where precise salt content is critical — confectionery, pickling, brining for fish and ham.
Environmental monitoring: Checking for salt intrusion into freshwater sources from road salt, industrial discharge, or seawater intrusion. Regular measurements document long-term trends.
Education: Primary and secondary school teaching in biology and chemistry. The refractometer is a clear example of how light refraction is used in practical measurement technology.
What the kit includes
RF20 refractometer with 0-100 ppt salinity scale, ATC compensation (10-30 °C), compact plastic construction, carrying case, calibration screwdriver, plastic pipette for sampling, calibration solution for verification.
1,607 SEK is the investment that makes professional salinity monitoring accessible to both hobbyists and professionals. For an aquarium owner with an investment of 20,000-50,000 SEK in aquarium, filter, coral and fish, the refractometer is a negligible part of the total cost — and at the same time the instrument that most directly affects the system’s long-term survival.
Read more: RF20 salinity refractometer 0-100 ppt in the shop →